| Current
range: Voltage range: Network parameters: Line Frequency range: Earth Leakage current: Connectors: Controls: Indicators: RF output: Insertion Loss: Transient Protection Level: Op. Temperature: Dimensions: Construction: |
up to 100A AC/DC
max. per line up to 275V AC/DC line-earth (440V rms AC line-line) 50W / 50mH dc to 100Hz 80mA (typ) @50Hz (measured according to EN61010-1) Line (input):6mm shrouded 'snap-lock' skts (L1, L2, L3, N, E) EUT (output):6mm shrouded 'snap-lock' skts (L1, L2, L3, N, E) Control:IEC/CEE22 input 240/120V AC 50/60Hz Remote: 5-pin DIN BNC: RF outputs, internally terminated at 50 ohms Line Monitor: rotary switch for selecting L1, L2, L3, or N Yellow LED's indicate monitored line 150kHz to 30MHz (Band B CISPR16 compliant) 0dB 150dBmV -5 to +45 deg. C 429(H) x 530(W) x 522(D)mm aluminium alloy instrument case, side extrusions incorporate carrying flange |
| Warranty
on Lisns All parts on these products are warranted by the manufacturer: Cranage EMC Technology Limited, Stable Court, Oakley, Nr. Market Drayton, Shropshire TF9 4AG: against defects in materials or workmanship for a period of 12 months from the date of purchase. |
|