A LISN is used in conjunction with a spectrum analyser or receiver for measuring high frequency noise conducted on AC/DC power lines. It is located between the incoming supply and the Equipment Under Test (EUT). In addition to complying with CISPR16 specifications for the industrial, residential, and commercial environments, the Cranage VN1-22S LISN contains a bi-directional transient voltage limiter and wideband power attenuator which prevents front-end damage to receivers and analysers.

Technical Specification

Current range:  
Voltage range:     
Network parameters:  
Line Frequency range:  
Earth Leakage current:
Connectors:       



Controls:   
Indicators:      
                      
RF output:    
Insertion Loss:     
Transient Protection Level:
Op. Temperature:       
Dimensions:                    
Construction:                   

up to 22A rms AC/DC max.
up to 275V rms AC/DC max.
50W / 50mH
dc to 100Hz
80mA (typ) @50Hz
Line (input): 4mm shrouded (L, E, N)
EUT (output): 4mm shrouded (L, E, N)
Control: IEC/CEE22 input 240/120V AC 50/60Hz
BNC: RF outputs (L, N), internally terminated at 50 ohms
Line Monitor: push-button for selecting L or N
Red LED indicates control circuit 'ON'
Yellow LED's indicate monitored line
150kHz to 30MHz (Band B CISPR16 compliant)
0dB
150dBmV
-5 to +45 deg. C
162(H) x 530(W) x 422(D)mm
aluminium alloy instrument case, side extrusions incorporate carrying flange

Warranty on Lisns